HOME > MOTION GUIDANCE > MOTION GUIDEWAYS > PRECISION, PRELOAD & ACCURACY

Euro-Bearings Home

MOTION GUIDE WAYS - DATA ON PRELOAD, PRECISION & ACCURACY

motion guidance systems accuracy

• Preload Class

CLASS
SYMBOL
PRELOAD (KgF)
VERY LIGHT PRELOAD
Z0
0
LIGHT PRELOAD
Z1
0.02Co
MEDIUM PRELOAD
Z2
0.05Co
HEAVY PRELOAD
Z3
0.08Co

• Accuracy Class (see dwg above)

ITEM / CLASS
NORMAL
HIGH
PRECISION
SUPER PRECISION
ULTRA PRECISION
Dim H Tolerance
+/- 0.15
+/-0.05
0 to -0.04
0 to -0.02
0 to -0.01
Dim N Tolerance
+/-0.10
+/-0.05
0 to -0.05
0 to -0.03
0 to -0.015
Dim variation of H
0.03
0.015
0.007
0.005
0.003
Dim variation of N
0.03
0.02
0.01
0.007
0.003
Running parallelism on Surface C to Surface A
Running parallelism on Surface D to Surface B

Back to Motion Guidance Index Back to Main Index